How Can We Help?
TC-4S replacement

Question
I am using TC-4S.
I would like to replace it, but is there any replacement?

Answer
Please refer to the table below for alternatives to TC-4S.
However, since the shape and specifications are different, it may not be possible to replace it depending on the application.
Please consider this carefully.
| Mode | Substitute | Remarks |
|---|---|---|
| 1 | TC-V6S | When using the proximity sensor as it is Set TC-V6S to “Negative Logic”. |
| 8 | KCV-4S | When using the proximity sensor as it is Set KCV-4S to “Negative Logic”. |
| 2 to 7 | None | Please contact the technical support desk. |
Wiring information
DipSW information
For the TC-V6S/KCV-4S, set DIP switches 2 and 4 to the ON position.
If DIP switch 9 on the TC-4S is set to ON, then set DIP switch 5 on the TC-V6S/KCV-4S to the ON position.
If DIP switch 9 on the TC-4S is set to ON, then set DIP switch 5 on the TC-V6S/KCV-4S to the ON position.
Inquiry
Technical support
Click here for inquiries by email
Click here for inquiries by email